1. Technical data |
|
Standard:IEC1008,GB16916, BS EN61008
Rated voltage)Un): 2pole:230VAC 4pole:400VAC
Rated current (In): 25,40,63A
Rated residual operating current (I△n):30,100,300,500mA
Rated residual non-operating current (I△no):0.5 I△n
Residual current off-time:≤ 0.1s
Minimum value of rated making and breaking capacity (1m): 1KA
Rated conditional short-circuit current (Inc): In=25,40A Inc=1500A In=63A Inc=3000A
Installation:On symmetrical DIN rail |
|
|
2. Applicable standards |
|
International standard:
IEC 61008-1 residual current operated without integral over current
Protection of household and similar uses (RCCB) |
|
|
|
3. Normal usage and mounting conditions: |
|
|
a) Ambient temperature: the breaker can work under ambient air temperature -25℃ ~+40℃;
b)Altitude: the breaker can work under altitude not exceed 2000m;
c)Class of pollution: the class of pollution is class 2;
d)Installation type: the installation type is Ⅲ;
e) Mounting position: the breaker can be mounted in rail, or horizontally, vertically. it will not decrease their electric features:
f)Environmental protection: Environmental factors are adequately considered in the design of circuit breaker, with many recoverable and degradable materials.
g)Power source in-line: the in-line can be connected from different directions, which will not affect its electric features. |
|
|
|
4. Main teachnical data
|
|
Model |
|
|
ML8 |
Number of poles |
|
|
2P 4P |
Rated current in |
|
A |
10 16 25 32 40 63 |
Rated frequency |
|
Hz |
50 |
Rated operating voltage Ue |
|
V |
230 400 |
Rated isolating voltage Ui |
|
V |
500 |
rated short-circuit making capacity Im |
|
A |
630 |
Rated limit short-circuit current Ic |
|
A |
6000 |
Rated residual actuating current I△n |
|
mA |
30 100 300 |
Rated residual non- actuating current I△no |
|
mA |
15 50 150 |
Breaking time I△=I△N I△=5I△N |
|
ms |
≤100 |
|
ms |
≤40 |
Frequency of operation cycle |
per hour |
time |
240 |
electrical |
time |
1000 |
non-electrical |
time |
2000 |
Level of protection |
|
|
IP20 |
Working feature with DC weight |
|
|
A,AC(type) |
Mounting type |
|
|
Rail plug-in |
Connection type |
|
|
Terminal with clip |
Ambient temperature |
Min/Max |
℃ |
-25/+40 |
Altitude |
Max |
m |
2000 |
Connection lead |
Min/Max |
mm2 |
1/25 |
Tightening torque |
|
N.m |
2 |
Extermal dimensions (LXWXH) |
2P |
mm |
82.5X36X76 |
4P |
mm |
82.5X72X76 |
Weight |
2P |
kg |
0.275 |
4P |
kg |
0.360 |
|
|
|
5. Outline installation dimensions |
|
Outline and installation dimensions, see table it is mounted by steal mounting quide rail, type TH35-7.5 |
|
|
|
|
|